Smart lighting

Switches, scenes and energy, on one lighting desk

MeetCarbon Cloud smart lighting keeps multi-vendor gateways, luminaires, groups, scenes and strategies on one ledger. On, off, brightness and color temperature go out by luminaire, group or scene. Energy is compared by device, circuit and area. Cameras and panic buttons on the pole stay in smart street lights. Whole-building electricity, water, gas and heat stay in the energy management system.

Multi-gateway
Vendor adapters, one control surface
Groups & scenes
Batch on, off and dim by space
Five strategies
Timer, sun, sensor, event, composite
Three bases
Metered, estimated or hybrid energy
Lighting overview
Sample data
96%
Online
78%
Lights on
186
Today
kWh · sample
Energy mix
  • Roads42%
  • Parking28%
  • Common areas18%
  • Offices12%
Open
  • Main-road circuit offlineImportant
  • Sunrise strategy failed onceNotice
Path

From gateway claim to energy review

Luminaires land on the ledger first, then groups, then automatic execution. Circuit energy is how you check that a strategy ran as intended.

  1. 01

    Connect a gateway

    Register vendor, address and project, test the link, then sync spaces and devices.

    Gateways
  2. 02

    Claim devices

    Claimed luminaires show online state, switch, brightness and color temperature.

    Device list
  3. 03

    Groups and scenes

    Group by road, floor or function. Save common brightness levels as one-tap scenes.

    Groups · scenes
  4. 04

    Strategies run

    Timer, sunrise, sensor, event or composite strategies hit their target by priority.

    Policy center
  5. 05

    Compare energy

    Read energy, power and on-hours by device, circuit, area, group or site.

    Energy overview
  6. 06

    Events and audit

    Offline, failed commands and manual actions stay in events, control logs and operation logs.

    Ops & audit
Tour

Walk the lighting desk menu

These eight items match the live overview, topology, devices, groups, strategies, energy and operations pages. Base settings are covered under onboarding.

Smart lighting / Overview

Overview

On site
In-page tabs
Online rateLights-on rateToday’s energy
This page answers

Start with whether the estate is online, how much is on, and how much energy landed today. Abnormal circuits drill down from here.

  • Online, lights-on and alarms on one screen
  • Switch site so projects are not blended
  • Sample or metered marks stay next to the numbers
SampleOnline rate
Online96%
Lights on78%
Today186 kWh · sample
Alarms2

Online rate and kilowatt-hours in the sample cards explain the layout. They are not a site’s operating result.

States

Luminaires, policies and energy bases stay distinct

Online does not mean switched on. A policy sends commands only while enabled. Energy figures need a metered, estimated or hybrid mark.

Luminaire

Comms and the switch are separate. Brightness is 0–100%. Color temperature is in kelvin.

  • Online
    Last report inside the offline threshold
    Online
  • Offline
    Comms lost, filed as a lighting event
    Offline
  • On
    Switch state is on
    On
  • Off
    Switch state is off
    Off

Policy

Types: timer, sunrise and sunset, sensor, event, composite. Disabled policies do not fire.

  • Enabled
    Sends to the target when conditions match
    On
  • Disabled
    Configuration stays, execution stops
    Off

Energy basis

The same energy page can switch basis so an estimate is not read as a meter.

  • Metered
    From a circuit or luminaire meter
    Meter
  • Estimated
    Power times hours on
    Estimate
  • Hybrid
    Meter where present, estimate elsewhere
    Hybrid

9 statesThe offline threshold is a minute setting in base configuration. Failed policy runs stay on the policy list. They are not rewritten as a successful lights-off.

Who uses it

Facilities, operations, energy and integrators open different pages

The same lights-on: facilities want the scene, operations want offline, energy wants the circuit, integrators want the gateway link.

Question to answer

Will the road and lobby follow the scene tonight?

What they check
  • Enabled timer and sunrise policies
  • Whether groups cover the main road and lobby
  • Whether the scene run succeeded
Modules
Groups & scenesPolicy centerOverview
Savings sketch

Estimate energy from power, hours and brightness

Move the four controls to see the gap between the baseline window and the strategy window. The result follows the inputs.

Baseline hours use full power. Strategy hours scale power by the brightness percent. The window is fixed at 30 days and shown beside the result.

Strategy window uses less
+15,360kWh
Sample energy saved
15,360 kWh
Sample bill gap
12,288 CNY
Sketch days
30

This sketch is a quantity illustration. It does not forecast a site savings rate and it is not a retrofit quote. Where meters exist, use the metered or hybrid figure in energy detail. Bills follow the local invoice.

Loop

See the lights, command them, then read the energy

A change starts on the overview and ends in the logs. Each step can return to the space tree and the group.

  1. 1
    Read the overview

    Online rate, lights-on rate and today’s energy decide whether to drill in.

  2. 2
    Locate on the tree

    Open a floor or road segment and confirm which group it is.

  3. 3
    Run a scene or one light

    Groups take a scene. One luminaire takes switch, brightness and color temperature.

  4. 4
    Policies fire by priority

    Enabled policies trigger on time. Failures stay on the list.

  5. 5
    Compare the circuit

    Pick metered, estimated or hybrid and read energy and on-hours.

  6. 6
    File the event

    Offline, control results and manual actions go to three logs.

Boundary

The luminaire ledger stays here

Switches, scenes, strategies and lighting energy live in smart lighting. Pole payloads, the building ledger, HVAC and protocol onboarding have their own products.

This product covers

  • Register, enable and connection-test multi-vendor gateways
  • Claim luminaires, then switch, brightness and color temperature
  • Group control and scene execution
  • Timer, sunrise, sensor, event and composite policies
  • Lighting energy overview and detail: metered, estimated, hybrid
  • Events, control log, comms and operation log

Commands go to a lighting gateway that is already connected. Electricity settlement stays on the utility bill. Emission reports stay in the inventory.

Go-live

Five steps to bring one estate online

Connect the gateway, claim devices, group them, enable one policy, then see the circuit on the energy page.

Before you start
  • 1Gateway vendor, address and project id
  • 2Building, floor or road list
  • 3Luminaires and their circuits
  • 4Energy basis: metered, estimated or hybrid

Turn on offline alarms and the minute threshold in base settings after the gateway is reporting steadily.

  1. 1
    Register the gateway

    Enter vendor type and address, then run the connection test.

    Done when · Test passes
  2. 2
    Sync and claim

    After spaces and devices sync, move them from unclaimed to the device list.

    Done when · Online state on the list
  3. 3
    Groups and scenes

    Group roads, parking and the lobby, and save two everyday scenes.

    Done when · Batch on and off works
  4. 4
    Enable one policy

    Pick timer or sunrise, set the target and priority, then enable it.

    Done when · Run history is visible
  5. 5
    Open energy

    Pick site and time window, confirm the basis, then export.

    Done when · Circuit energy exports
Platform

Many sites, many vendors, an action trail

The same lighting desk separates projects. Manual commands and policy triggers both leave a record. Deployment and price are on the pricing page.

Many projects

Campus, building and road keep their own overview, devices and energy.

Vendor adapters

Gateways join by vendor type. The control surface stays switch, brightness and color temperature.

Action trail

Manual control and policy triggers land in the operation log, control log and run history.

Energy export

Overview and detail export by time window for the monthly review.

SaaS

Opened per project, on the same MeetCarbon Cloud account as the other building products.

On-premises

When gateways can only reach the intranet, the platform can sit on the customer side.

FAQ

Policies, savings rates and neighbors

Four boundaries customers check before go-live.

Once a policy is enabled, do the lights change on their own?

When enabled, a matching trigger sends switch, brightness, color temperature or a scene to the target group or device. The result is in run history and the control log. Disabled policies do not fire. People can still operate a device or a group by hand.

Is the savings rate on the page a commitment?

Figures on the overview and in this page’s sketch are marked as samples. Site energy follows the detail page and is marked metered, estimated or hybrid. Bills follow the local invoice.

How does this split from smart street lights?

Smart lighting covers switch, brightness, scenes, policies and lighting energy. Poles, cameras, broadcast, environment sensing and panic buttons stay in smart street lights.

How does this split from EMS and smart HVAC?

Lighting energy stays on its circuits here and can roll into the EMS breakdown. Temperature, fan and heating or cooling hours stay in smart HVAC and are not sent from a lighting policy.

Lay out one campus, lights and circuits

Tell us the gateway vendor, whether the scope is buildings or roads, and who switches lights by hand today. We demo groups, policies and the energy compare on that structure.